Elevator Control Boards


Customize your access devices to your space. The DKS 2348 Elevator Control System provides complete elevator security typically used in high rise condominium, apartment, or office building applications to restrict which floors visitors and building residents have access to.


Elevator Control Boards

 

1830 Series Telephone Entry Expansion

The DKS 2348 Elevator Control System provides complete elevator security that is typically used in high rise condominium, apartment, or office building applications. The system will restrict which floor a visitor has access to via the elevator after they have been granted access by a building resident; and, is programmable to restrict building residents to certain floors or grant them access to all floors. Residents must use their access card (or other access control device) to “turn on” the floor buttons that they have access to.

  • Restricts which floor a -visitor has access to
  • Also can be programmed to restrict residents to certain floors, or grant them access to all floors
  • Elevator users must have a valid access card to access restricted floors
  • Control up to 8 elevators, with each elevator serving up to 64 floors
  • “Call” function automatically sends elevator to ground floor when access has been granted
  • Must be interfaced with a DKS model 1833, 1835, 1837 telephone entry or 1838 access control system

 


Features

 

DKS Cloud Programming

Program from the DKS Cloud (requires DKS connection service subscription) with your laptop or tablet or from your dedicated PC using the Remote Account Manager software. The Cloud Account Manager was developed for administrators and staff of multi-unit and multi-use buildings to easily program and manage their Entry Systems from any device, anywhere, at any time. Available with DKS Cellular, VoIP Internet or IM Server subscriptions.

 

Seamless Integration

Create a full system with solutions designed to work together by connecting DKS Telephone Entry or Access Control products.

 

 

Call Relay

“Call” function automatically sends elevator to ground floor when access has been granted.

 

Powerful Access 
  • Restricts which floor a visitor has access to
  • Also can be programmed to restrict residents to certain floors, or grant them access to all floors
  • Elevator users must have a valid access card to access restricted floors
Interface With

Must be interfaced with a DKS model 1833, 1835, 1837 telephone entry or 1838 access control system

Capacity

Of the system is easily expanded to control 8 elevator shafts with up to 64 floors each.

Technical Specifications

 

Specifications

2348-040 ELEVATOR CONTROL BOARD

  • Each elevator board can control up to 16 floors, with a maximum of four (4) elevator control boards interfaced with a single elevator for a total of 64 floors. Each access controller can control up to eight (8) elevators in this manner.
  • Includes mounting hardware

2348-080 ELEVATOR CONTROL BOARD CABINET

  • Lockable enclosure for two (2) elevator control boards (2nd board mounts on cabinet door)
  • Includes one (1) 2348‐010 and power transformer
  • Use part number 2348‐040 to order additional board

2348-081 ELEVATOR CONTROL BOARDS CABINET

  • Lockable enclosure for up to four (4) elevator control boards (boards 3 and 4 mount on cabinet door)
  • Includes one (1) 2348‐010 and power transformer
  • Use part number 2348‐040 to order additional boards

OPTIONAL

  • Wireless Weigand and wireless RS-232 interface devices are available

OPERATING TEMP
32°F to 140°F 0°C to 62°C

  • The elevator control cabinets are intended to be installed in the elevator electrical room in close proximity to the elevator electronic control panel

ACCESSORIES

  • Transformer box
  • Card Readers
SHIPPING WEIGHT

Large cabinets approximately 45 lbs (20.4 kg)
Small cabinets approximately 25 lbs (11.3 kg)

 

Mechanical

CAPACITY

  • Each elevator control board interfaces with up to 16 floor buttons in the elevator car
  • Four (4) elevator control boards can be interfaced with each other to provide control of up to 64 floors for a single elevator shaft
  • Overall, the system can accommodate up to eight (8) elevator shafts with each shaft capable of serving up to 64 floors
  • Small cabinet can accommodate two (2) 2348 elevator control boards
  • Large cabinet: can accommodate four (4) 2348 elevator control boards
  • Cabinets include ribbon cables to interface the boards and a 16 VAC, 40 VA power transformer
  • Enclosures are NEMA 4x rated

CONTROL RELAYS

  • Floor Relays (each board): 16
  • Call Relay (master board only) 1
  • Relay contacts are rated at 115 VAC, 1 amp
  • Relays can be set for normally closed (N.C.) or normally open (N.O.) operation

PROGRAMMING METHODS

  • Program via internet (using DKS servers), modem, or RS-232 interface with V 6.5 Remote Account Manager

ELECTRICAL REQUIREMENTS

  • A single 16 VAC, 40 VA transformer can power up to four (4) 2348-010 elevator control boards.
  • Input power: 16 VAC, 40 VA UL Listed transformer provided Current draw: 250ma

INSTALLATION
Installation of this product will require wiring interfaces from the elevator electronic control to the 2348 elevator control board. A weigand wire cable (see options) will also be routed from the elevator car along the elevator electrical umbilical to the access control system. Because of these electrical interfaces, the installation of this product must be coordinated with a licensed elevator servicing company.

NOTE: The 2348 elevator control board is not a stand alone device. It must be interfaced with a DKS model 1833, 1835 or 1837 telephone entry system, or a DKS model 1838 access control system.

  

 

  


Tech Support

Quick Start Guides icons accessory

Quick Start Guides

Owners Manuals icons accessory

Owner’s Manuals

Accessory Manuals icon accessory

Accessory Manuals

Easy Connect Manuals icon accessory

Easy Connect Manuals

Tech Tip Videos icons accessory

Tech Tip Videos


Resources

2348 Elevator Control
Elevator Control Board 2348 Series
Scroll to Top
Skip to content